3D ultrasound examination of large organs

Freehand 3D ultrasound is particularly appropriate for the measurement of organ volumes. For small organs, which can be fully examined with a single sweep of the ultrasound probe, the results are known to be much more accurate than those using conventional 2D ultrasound. However, large or complex shaped organs are difficult to quantify in this manner because multiple sweeps are required to cover the entire organ. Typically, there are significant registration errors between the various sweeps, which generate artifacts in an interpolated voxel array, making segmentation of the organ very difficult. This report describes how sequential freehand 3D ultrasound can be used to measure the volume of large organs without the need for an interpolated voxel array. The method is robust to registration errors and sweep orientation , as demonstrated in simulation and also using in vivo scans of a human liver, where a volume measurement precision of ±5% is achieved.

[1]  S. Hughes,et al.  Application of a new discreet form of Gauss' theorem for measuring volume. , 1996, Physics in medicine and biology.

[2]  Robert Rohling,et al.  A comparison of freehand three-dimensional ultrasound reconstruction techniques , 1999, Medical Image Anal..

[3]  O. Gilja,et al.  In vivo comparison of 3D ultrasonography and magnetic resonance imaging in volume estimation of human kidneys. , 1995, Ultrasound in medicine & biology.

[4]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[5]  J. Waterton,et al.  Volumetric assessment of carotid artery bifurcation using freehand-acquired, compound 3D ultrasound. , 1999, The British journal of radiology.

[6]  J G Duncan,et al.  Liver volume determination by ultrasound: a feasibility study. , 1976, The British journal of radiology.

[7]  David J. Hawkes,et al.  Volume estimation from sparse planar images using deformable models , 1999, Image Vis. Comput..

[8]  Daniel Cohen-Or,et al.  Real-Time Ultrasound Imaging Simulation , 1998, Real Time Imaging.

[9]  V Siskind,et al.  Measurement of liver volume using water delay ultrasonography. , 1986, Diagnostic imaging in clinical medicine.

[10]  Andrew H. Gee,et al.  Stradx: real-time acquisition and visualisation of freehand 3D ultrasound , 1998 .

[11]  Andrew H. Gee,et al.  Fast surface and volume estimation from non-parallel cross-sections, for freehand 3-D ultrasound , 1998 .

[12]  T A Whittingham,et al.  New and future developments in ultrasonic imaging. , 1997, The British journal of radiology.

[13]  S N Rasmussen,et al.  Liver volume determination by ultrasonic scanning. , 1972, Danish medical bulletin.

[14]  Robert Rohling,et al.  Three-dimensional spatial compounding of ultrasound images , 1997, Medical Image Anal..

[15]  P Vock,et al.  Measurement of liver volume by ultrasound and computed tomography , 1983, Journal of clinical ultrasound : JCU.

[16]  T. Nelson,et al.  Three‐dimensional ultrasound , 1999, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[17]  Andrew H. Gee,et al.  Non-planar Reslicing for Freehand 3D Ultrasound , 1999, MICCAI.

[18]  D. King,et al.  Freehand three-dimensional echocardiography for measurement of left ventricular mass: in vivo anatomic validation using explanted human hearts. , 1997, Journal of the American College of Cardiology.

[19]  D F Leotta,et al.  Estimation of the human liver volume and configuration using three-dimensional ultrasonography: effect of a high-caloric liquid meal. , 1998, Ultrasound in medicine & biology.

[20]  Robert Rohling,et al.  Automatic registration of 3-D ultrasound images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[21]  Andrew H. Gee,et al.  Regularised marching tetrahedra: improved iso-surface extraction , 1999, Comput. Graph..

[22]  S Perring,et al.  Measurement of placental volume with real‐time ultrasound in mid‐pregnancy , 1994, Journal of clinical ultrasound : JCU.

[23]  R G Aarnink,et al.  Reproducibility of prostate volume measurements from transrectal ultrasonography by an automated and a manual technique. , 1996, British journal of urology.

[24]  A. Fenster,et al.  3-D ultrasound imaging: a review , 1996 .

[25]  J. Udupa,et al.  Shape-based interpolation of multidimensional objects. , 1990, IEEE transactions on medical imaging.

[26]  J Deng,et al.  Fetal echocardiography in three and four dimensions. , 1996, Ultrasound in medicine & biology.

[27]  Yoshiaki Watanabe,et al.  A Method for Volume Estimation by Using Vector Areas and Centroids of Serial Cross Sections , 1982, IEEE Transactions on Biomedical Engineering.

[28]  D J Coleman,et al.  Three-dimensional ultrasound imaging. Clinical applications. , 1998, Ophthalmology.