Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates

OBJECTIVE Brain-computer interfaces (BCIs) using chronically implanted intracortical microelectrode arrays (MEAs) have the potential to restore lost function to people with disabilities if they work reliably for years. Current sensors fail to provide reliably useful signals over extended periods of time for reasons that are not clear. This study reports a comprehensive retrospective analysis from a large set of implants of a single type of intracortical MEA in a single species, with a common set of measures in order to evaluate failure modes. APPROACH Since 1996, 78 silicon MEAs were implanted in 27 monkeys (Macaca mulatta). We used two approaches to find reasons for sensor failure. First, we classified the time course leading up to complete recording failure as acute (abrupt) or chronic (progressive). Second, we evaluated the quality of electrode recordings over time based on signal features and electrode impedance. Failure modes were divided into four categories: biological, material, mechanical, and unknown. MAIN RESULTS Recording duration ranged from 0 to 2104 days (5.75 years), with a mean of 387 days and a median of 182 days (n = 78). Sixty-two arrays failed completely with a mean time to failure of 332 days (median = 133 days) while nine array experiments were electively terminated for experimental reasons (mean = 486 days). Seven remained active at the close of this study (mean = 753 days). Most failures (56%) occurred within a year of implantation, with acute mechanical failures the most common class (48%), largely because of connector issues (83%). Among grossly observable biological failures (24%), a progressive meningeal reaction that separated the array from the parenchyma was most prevalent (14.5%). In the absence of acute interruptions, electrode recordings showed a slow progressive decline in spike amplitude, noise amplitude, and number of viable channels that predicts complete signal loss by about eight years. Impedance measurements showed systematic early increases, which did not appear to affect recording quality, followed by a slow decline over years. The combination of slowly falling impedance and signal quality in these arrays indicates that insulating material failure is the most significant factor. SIGNIFICANCE This is the first long-term failure mode analysis of an emerging BCI technology in a large series of non-human primates. The classification system introduced here may be used to standardize how neuroprosthetic failure modes are evaluated. The results demonstrate the potential for these arrays to record for many years, but achieving reliable sensors will require replacing connectors with implantable wireless systems, controlling the meningeal reaction, and improving insulation materials. These results will focus future research in order to create clinical neuroprosthetic sensors, as well as valuable research tools, that are able to safely provide reliable neural signals for over a decade.

[1]  E. Manuelidis,et al.  Histopathological changes produced by implanted electrodes in cat brains; comparison with histopathological changes in human and experimental puncture wounds. , 1957, Journal of neurosurgery.

[2]  R L Schultz,et al.  The ultrastructure of the sheath around chronically implanted electrodes in brain , 1976, Journal of neurocytology.

[3]  G. Loeb,et al.  Parylene as a Chronically Stable, Reproducible Microelectrode Insulator , 1977, IEEE Transactions on Biomedical Engineering.

[4]  T. Yuen,et al.  Tissue response to potential neuroprosthetic materials implanted subdurally. , 1987, Biomaterials.

[5]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[6]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[7]  J. Donoghue,et al.  Neuronal Interactions Improve Cortical Population Coding of Movement Direction , 1999, The Journal of Neuroscience.

[8]  X Liu,et al.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[9]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[10]  J. W. Schultze,et al.  Passivation and corrosion of microelectrode arrays , 1999 .

[11]  E. Maynard,et al.  A technique to prevent dural adhesions to chronically implanted microelectrode arrays , 2000, Journal of Neuroscience Methods.

[12]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[13]  Patrick A. Tresco,et al.  Impedance characterization of microarray recording electrodes in vitro , 2005, IEEE Transactions on Biomedical Engineering.

[14]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[15]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[16]  Daniel R Merrill,et al.  Impedance characterization of microarray recording electrodes in vitro , 2005, IEEE Trans. Biomed. Eng..

[17]  R. Bellamkonda,et al.  Biomechanical analysis of silicon microelectrode-induced strain in the brain , 2005, Journal of neural engineering.

[18]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[19]  R. Normann,et al.  A method for pneumatically inserting an array of penetrating electrodes into cortical tissue , 2006, Annals of Biomedical Engineering.

[20]  K. E. Jones,et al.  A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.

[21]  D. Humphrey,et al.  Long-term gliosis around chronically implanted platinum electrodes in the Rhesus macaque motor cortex , 2006, Neuroscience Letters.

[22]  P. E. K. Donaldson,et al.  Aspects of silicone rubber as an encapsulant for neurological prostheses , 2006, Medical and Biological Engineering and Computing.

[23]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[24]  Karen L. Smith,et al.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion , 2006, Journal of neural engineering.

[25]  E. Schmidt,et al.  Long-term implants of Parylene-C coated microelectrodes , 2006, Medical and Biological Engineering and Computing.

[26]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[27]  Ravi V. Bellamkonda,et al.  Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes , 2007, Brain Research.

[28]  Michael J. Black,et al.  Neural control of computer cursor velocity by decoding motor cortical spiking activity in humans with tetraplegia , 2008, Journal of neural engineering.

[29]  A. Levey,et al.  Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration , 2009, Journal of neural engineering.

[30]  Philippe Renaud,et al.  In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays , 2009, IEEE Transactions on Biomedical Engineering.

[31]  T. Stieglitz,et al.  Characterization of parylene C as an encapsulation material for implanted neural prostheses. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[32]  Justin C. Sanchez,et al.  Corrosion of tungsten microelectrodes used in neural recording applications , 2011, Journal of Neuroscience Methods.

[33]  E. Halgren,et al.  Single-neuron dynamics in human focal epilepsy , 2011, Nature Neuroscience.

[34]  Vikash Gilja,et al.  Long-term Stability of Neural Prosthetic Control Signals from Silicon Cortical Arrays in Rhesus Macaque Motor Cortex , 2010 .

[35]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[36]  Justin C. Sanchez,et al.  Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing , 2012, Journal of neural engineering.

[37]  Arjun K. Bansal,et al.  Decoding 3D reach and grasp from hybrid signals in motor and premotor cortices: spikes, multiunit activity, and local field potentials. , 2012, Journal of neurophysiology.

[38]  Garrett B Stanley,et al.  The impact of chronic blood-brain barrier breach on intracortical electrode function. , 2013, Biomaterials.

[39]  Arto Nurmikko,et al.  An implantable wireless neural interface for recording cortical circuit dynamics in moving primates , 2013, Journal of neural engineering.

[40]  Jeffrey R Capadona,et al.  The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes. , 2013, Biomaterials.

[41]  James W. Fawcett,et al.  The astrocyte/meningeal cell interface – a barrier to successful nerve regeneration? , 2001, Cell and Tissue Research.

[42]  William J Tyler,et al.  A quantitative overview of biophysical forces impinging on neural function , 2013, Physical biology.