Robot assisted internal mammary artery detection for coronary revascularisation surgery

This paper presents a semi-automatic robotic system supporting a surgeon in the harvesting of the internal mammary artery (IMA) for an open chested intervention in coronary revascularisation surgery. The versatile surgical lightweight robot MIRO developed at DLR (German Aerospace Center) is used to detect and mark the path of the IMA at the inner side of the thoracic wall. The robot is equipped with a tool combining a Doppler ultrasonography (US) probe and a medical marker pen. The position of the IMA is extracted from the US-images to place the tool above the artery via visual servoing. Additionally, the robot moves the tool in direction of the artery to mark the location of the IMA on it's path. To achieve an ideal contact situation for US-imaging along the whole path the contact force between tissue and probe is controlled according to force measurements based on the internal torque sensors of the robot. The evaluation of the robotic system by an animal experiment shows that the system is capable of robustly detecting the IMA.

[1]  Early Experience of Robotic-Assisted Coronary Artery Bypass Grafting , 2006 .

[2]  Thomas A Vassiliades,et al.  Technical aids to performing thoracoscopic robotically-assisted internal mammary artery harvesting. , 2002, The heart surgery forum.

[3]  M.P. Fronheiser,et al.  3-D ultrasound guidance of surgical robotics: a feasibility study , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Alin Albu-Schäffer,et al.  A passivity based Cartesian impedance controller for flexible joint robots - part II: full state feedback, impedance design and experiments , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[5]  M. Spong Modeling and Control of Elastic Joint Robots , 1987 .

[6]  A. Vineberg,et al.  ANASTOMOSIS BETWEEN CORONARY VESSELS AND INTERNAL MAMMARY ARTERY. , 1947, Canadian Medical Association journal.

[7]  Thoracoscopic IMA Takedown , 2000, Journal of cardiac surgery.

[8]  Robert D. Howe,et al.  Tactile tracking of arteries in robotic surgery , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[9]  Alin Albu-Schäffer,et al.  MIMO State Feedback Controller for a Flexible Joint Robot with Strong Joint Coupling , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[10]  Alin Albu-Schäffer,et al.  The DLR MIRO: a versatile lightweight robot for surgical applications , 2008, Ind. Robot.

[11]  Alessandro De Luca,et al.  Friction observer and compensation for control of robots with joint torque measurement , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[12]  Wilhelm Sch Berle Ultrasonography in Vascular Diagnosis , 2008 .

[13]  G. Laufer,et al.  Robotic endoscopic left internal mammary artery harvesting: what have we learned after 100 cases? , 2007, The Annals of thoracic surgery.

[14]  Alin Albu-Schäffer,et al.  A passivity based Cartesian impedance controller for flexible joint robots - part I: torque feedback and gravity compensation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[15]  Volkmar Falk,et al.  Medical Robotics in Cardiac Surgery , 2008 .

[16]  B Kiaii,et al.  Robot-assisted computer enhanced closed-chest coronary surgery: preliminary experience using a Harmonic Scalpel and ZEUS. , 2000, The heart surgery forum.