Assistive technology and robotic control using motor cortex ensemble‐based neural interface systems in humans with tetraplegia

This review describes the rationale, early stage development, and initial human application of neural interface systems (NISs) for humans with paralysis. NISs are emerging medical devices designed to allow persons with paralysis to operate assistive technologies or to reanimate muscles based upon a command signal that is obtained directly from the brain. Such systems require the development of sensors to detect brain signals, decoders to transform neural activity signals into a useful command, and an interface for the user. We review initial pilot trial results of an NIS that is based on an intracortical microelectrode sensor that derives control signals from the motor cortex. We review recent findings showing, first, that neurons engaged by movement intentions persist in motor cortex years after injury or disease to the motor system, and second, that signals derived from motor cortex can be used by persons with paralysis to operate a range of devices. We suggest that, with further development, this form of NIS holds promise as a useful new neurotechnology for those with limited motor function or communication. We also discuss the additional potential for neural sensors to be used in the diagnosis and management of various neurological conditions and as a new way to learn about human brain function.

[1]  John P. Donoghue,et al.  Connecting cortex to machines: recent advances in brain interfaces , 2002, Nature Neuroscience.

[2]  J. Donoghue,et al.  Neuronal Interactions Improve Cortical Population Coding of Movement Direction , 1999, The Journal of Neuroscience.

[3]  Christina M Krause,et al.  Test-retest consistency of the event-related desynchronization/event-related synchronization of the 4–6, 6–8, 8–10 and 10–12 Hz frequency bands during a memory task , 2001, Clinical Neurophysiology.

[4]  Jonathan R Wolpaw,et al.  Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Nicholas G. Hatsopoulos,et al.  Brain-machine interface: Instant neural control of a movement signal , 2002, Nature.

[6]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[7]  D. Kipke,et al.  Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Kirk Jeffrey,et al.  Machines in Our Hearts: The Cardiac Pacemaker, the Implantable Defibrillator, and American Health Care , 2002 .

[9]  J. Mcilwain Population coding: a historical sketch. , 2001, Progress in Brain Research.

[10]  T. Bullock,et al.  Signals and signs in the nervous system: the dynamic anatomy of electrical activity is probably information-rich. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[11]  S. Meagher Instant neural control of a movement signal , 2002 .

[12]  Wei Wu,et al.  Bayesian Population Decoding of Motor Cortical Activity Using a Kalman Filter , 2006, Neural Computation.

[13]  F. Lacquaniti,et al.  Parieto-frontal coding of reaching: an integrated framework , 1999, Experimental Brain Research.

[14]  Dennis J. McFarland,et al.  Brain-computer interface (BCI) operation: signal and noise during early training sessions , 2005, Clinical Neurophysiology.

[15]  Matthew Fellows,et al.  Robustness of neuroprosthetic decoding algorithms , 2003, Biological Cybernetics.

[16]  Byron M. Yu,et al.  A high-performance brain–computer interface , 2006, Nature.

[17]  Jonathan R Wolpaw,et al.  Brain–computer interfaces as new brain output pathways , 2007, The Journal of physiology.

[18]  R. Bellamkonda,et al.  Biomechanical analysis of silicon microelectrode-induced strain in the brain , 2005, Journal of neural engineering.

[19]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[20]  J. Donoghue,et al.  Neural discharge and local field potential oscillations in primate motor cortex during voluntary movements. , 1998, Journal of neurophysiology.

[21]  Nicholas G Hatsopoulos,et al.  Encoding in the motor cortex: was evarts right after all? Focus on "motor cortex neural correlates of output kinematics and kinetics during isometric-force and arm-reaching tasks". , 2005, Journal of neurophysiology.

[22]  J. Kalaska,et al.  Cerebral cortical mechanisms of reaching movements. , 1992, Science.

[23]  W. B. Fye,et al.  Machines in Our Hearts: The Cardiac Pacemaker, the Implantable Defibrillator, and American Health Care , 2002 .

[24]  C. Mehring,et al.  Comparing information about arm movement direction in single channels of local and epicortical field potentials from monkey and human motor cortex , 2004, Journal of Physiology-Paris.

[25]  J. Anthony Movshon,et al.  Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex , 2007, The Journal of Neuroscience.

[26]  R. Andersen,et al.  Selecting the signals for a brain–machine interface , 2004, Current Opinion in Neurobiology.

[27]  C. Stevens,et al.  Neural Coding: The enigma of the brain , 1995, Current Biology.

[28]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[29]  G. Schalk,et al.  The emerging world of motor neuroprosthetics: a neurosurgical perspective. , 2006, Neurosurgery.

[30]  Dean J Krusienski,et al.  A comparison of classification techniques for the P300 Speller , 2006, Journal of neural engineering.

[31]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.

[32]  M. Morrell Brain stimulation for epilepsy: can scheduled or responsive neurostimulation stop seizures? , 2006, Current opinion in neurology.

[33]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.

[34]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[35]  G. Pfurtscheller,et al.  Event-related dynamics of cortical rhythms: frequency-specific features and functional correlates. , 2001, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[36]  J. Wolpaw,et al.  A P300 event-related potential brain–computer interface (BCI): The effects of matrix size and inter stimulus interval on performance , 2006, Biological Psychology.

[37]  M. Nicolelis,et al.  Optimizing a Linear Algorithm for Real-Time Robotic Control using Chronic Cortical Ensemble Recordings in Monkeys , 2004, Journal of Cognitive Neuroscience.

[38]  H. Alkadhi,et al.  Localization of the motor hand area to a knob on the precentral gyrus. A new landmark. , 1997, Brain : a journal of neurology.

[39]  W.R. Patterson,et al.  Development of a chipscale integrated microelectrode/microelectronic device for brain implantable neuroengineering applications , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[40]  Thilo Deckersbach,et al.  Functional Imaging of Mood and Anxiety Disorders , 2006, Journal of neuroimaging : official journal of the American Society of Neuroimaging.