Multimodal Approach to Remove Ocular Artifacts from EEG Signals Using Multiple Measurement Vectors

This paper deals with the extraction of eye-movement artifacts from EEG data using a multimodal approach. The gaze signals, recorded by an eye-tracker, share a similar temporal structure with the artifacts induced in EEG recordings by ocular movements. The proposed approach consists in estimating this specific common structure using Multiple Measurement Vectors which is then used to denoise the EEG data. This method can be used on single trial data and can be extended to multitrial data subject to some additional preprocessing. Finally, the proposed method is applied to gaze and EEG experimental data and is compared with some popular algorithms for eye movement artifact correction from the literature.

[1]  Bertrand Rivet,et al.  Comparison between adjar and xDawn algorithms to estimate Eye-Fixation Related Potentials distorted by overlapping , 2015, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER).

[2]  John Shawe-Taylor,et al.  Canonical Correlation Analysis: An Overview with Application to Learning Methods , 2004, Neural Computation.

[3]  M. Kowalski Sparse regression using mixed norms , 2009 .

[4]  Bhaskar D. Rao,et al.  Sparse solutions to linear inverse problems with multiple measurement vectors , 2005, IEEE Transactions on Signal Processing.

[5]  G. Pfurtscheller,et al.  A fully automated correction method of EOG artifacts in EEG recordings , 2007, Clinical Neurophysiology.

[6]  Fernando De la Torre,et al.  Generalized time warping for multi-modal alignment of human motion , 2012, 2012 IEEE Conference on Computer Vision and Pattern Recognition.

[7]  Richard C. Burgess,et al.  Effects of eyelid closure, blinks, and eye movements on the electroencephalogram , 2005, Clinical Neurophysiology.

[8]  Pierre Comon,et al.  Multimodal approach to estimate the ocular movements during EEG recordings: A coupled tensor factorization method , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[9]  Michael I. Jordan,et al.  A General Analysis of the Convergence of ADMM , 2015, ICML.

[10]  Stephen P. Boyd,et al.  Distributed Optimization and Statistical Learning via the Alternating Direction Method of Multipliers , 2011, Found. Trends Mach. Learn..

[11]  Yonina C. Eldar,et al.  Average Case Analysis of Multichannel Sparse Recovery Using Convex Relaxation , 2009, IEEE Transactions on Information Theory.

[12]  Pierre Comon,et al.  Handbook of Blind Source Separation: Independent Component Analysis and Applications , 2010 .

[13]  T. Sejnowski,et al.  Removing electroencephalographic artifacts by blind source separation. , 2000, Psychophysiology.

[14]  Donald J. Berndt,et al.  Using Dynamic Time Warping to Find Patterns in Time Series , 1994, KDD Workshop.

[15]  H. Semlitsch,et al.  A solution for reliable and valid reduction of ocular artifacts, applied to the P300 ERP. , 1986, Psychophysiology.