Adaptive Cancellation of Floor Vibrations in Standing Ballistocardiogram Measurements Using a Seismic Sensor as a Noise Reference

An adaptive noise canceller was used to reduce the effect of floor vibrations on ballistocardiogram (BCG) measurements from a modified electronic bathroom scale. A seismic sensor was placed next to the scale on the floor and used as the noise reference input to the noise canceller. BCG recordings were acquired from a healthy subject while another person stomped around the scale, thus causing increased floor vibrations. The noise canceller substantially eliminated the artifacts in the BCG signal due to these vibrations without distorting the morphology of the measured BCG. Additionally, recordings were obtained from another subject standing inside a parked bus while the engine was running. The artifacts due to the vibrations of the engine, and the other vehicles moving on the road next to the bus, were also effectively eliminated by the noise canceller. The system with automatic floor vibration cancellation could be used to increase BCG measurement robustness in home monitoring applications. Additionally, the noise cancellation approach may enable BCG recording in ambulances-or other transport vehicles-where noninvasive hemodynamic monitoring may otherwise not be feasible.

[1]  Howard J. Curtis,et al.  THE DESIGN OF THE BALLISTOCARDIOGRAPH , 1944 .

[2]  Gregory T. A. Kovacs,et al.  Non-invasive measurement of Valsalva-induced hemodynamic changes on a bathroom scale Ballistocardiograph , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Gregory T. A. Kovacs,et al.  Evaluating the Foot Electromyogram Signal as a Noise Reference for a Bathroom Scale Ballistocardiogram Recorder , 2008, 2008 21st IEEE International Symposium on Computer-Based Medical Systems.

[4]  Richard M. Wiard,et al.  Robust ballistocardiogram acquisition for home monitoring , 2009, Physiological measurement.

[5]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[6]  W DOCK,et al.  Some technics for recording the ballistocardiogram directly from the body. , 1949, The American journal of medicine.

[7]  S. Thomas Alexander,et al.  Adaptive Signal Processing , 1986, Texts and Monographs in Computer Science.

[8]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .

[9]  J. Alihanka,et al.  A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration. , 1981, The American journal of physiology.

[10]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[11]  A. J. Williams,et al.  A Self-Balancing Bridge with Range and Precision Adequate for a Platinum Thermometer , 1966 .

[12]  A. Varri,et al.  A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.